快速法质粒中量提取试剂盒
Fastfilter Plasmid DNA Midi Kit
产品编号 | 产品名称 | 包装规格 | 目录价 |
D6905-01 | 快速法质粒中量提取试剂盒 | 5T | 320 |
D6905-03 | 快速法质粒中量提取试剂盒 | 25T | 1350 |
D6905-04 | 快速法质粒中量提取试剂盒 | 100T | 4950 |
产品介绍
The E.Z.N.A.® FastFilter Plasmid DNA Midi Kit combines the convenience of spin columns with the speed of syringe filters to ease large-scale plasmid preparations. The system utilizes Lysate Clearance Filter Syringes instead of centrifugation to rapidly clear bacterial lysates post-alkaline lysis and follows a simple “bind-wash-elute” procedure to deliver high quality plasmid DNA. The yields vary according to plasmid copy number, E. coli strain, and growth conditions. 15-50 mL of bacterial cultures in LB medium typically produces up to 200 µg of high copy number plasmid DNA. Up to 100 mL of culture may be processed when working with low copy number plasmid. The system uses centrifugation or vacuum technology for plasmid purification and eliminates the time-consuming gravity-flow columns that require alcohol precipitation. Purified plasmid DNA is suitable for automated fluorescent DNA sequencing (typical reads exceed 800 bp), restriction enzyme digestion, ligation, PCR, in vitro transcription, transformation, and other applications.
参数
FEATURES | SPECIFICATIONS |
Downstream Application | Cloning, sequencing, transformation, PCR, restriction digestion, ligation, in vitro transcription etc. |
Starting material | 15–50 mL LB culture with OD600 between 2 and 3; or equivalent |
Plasmid type | High-copy, low-copy, cosmid DNA |
Processing mode | Manual (centrifugation or vacuum) |
Throughput | 1 – 24 |
DNA binding technology | Silica Midi Spin Column |
Lysate clearance method | Filtration using Lysate clearance syringe |
Processing time | 40 minutes |
Yield | 100–250 μg for high copy-number; 10–50 μg for low copy-number |
Special note | Lysate clearance syringe for rapid sample processing |
组分
FastFilter Plasmid Midi Kit | D6905-00 | D6905-03 | D6905-04 |
Purifications | 2 | 25 | 100 |
HiBind® DNA Midi Columns | 2 | 25 | 100 |
15 mL Collection Tubes | 2 | 25 | 100 |
Lysate Clearance Filter Syringe | 2 | 25 | 100 |
Solution I | 6 mL | 80 mL | 270 mL |
Solution II | 6 mL | 80 mL | 270 mL |
N3 Buffer | 4 mL | 40 mL | 140 mL |
GBT Buffer | 6 mL | 60 mL | 230 mL |
HBC Buffer | 5 mL | 58 mL | 250 mL |
DNA Wash Buffer | 5 mL | 40 mL | 200 mL |
RNase A | 20 μL | 300 μL | 1.2 mL |
Elution Buffer | 5 mL | 60 mL | 250 mL |
User Manual | ✓ | ✓ | ✓ |
流程
Centrifugation Protocol
Pellet by Centrifugation
Resuspend, Lyse, Neutralize
Add GBT Lysis Buffer
Transfer Lysate to Lysate Clearance Syringe
Insert Plunger into Syringe & Clear Lysate into Centrifuge Tube
Pass Lysate through Column
Wash 3X
Transfer Column to Collection Tube & Centrifuge to Dry HiBind® matrix
Transfer Column to new Centrifuge Tube & Centrifuge to Elute DNA
Vacuum Protocol
Pellet by Centrifugation
Resuspend, Lyse, Neutralize
Add GBT Lysis Buffer
Transfer Lysate to Lysate Clearance Syringe
Insert Plunger into Syringe & Clear Lysate into Centrifuge Tube
Prepare Vacuum Manifold
Insert Column into Luer Connector on Vacuum Manifold
Pass Lysate through Column
Wash 3X
Transfer Column to Collection Tube & Centrifuge to Dry HiBind® matrix
Transfer Column to new Centrifuge Tube & Centrifuge to Elute DNA